IMPORTANT:
Device Type: | Flash Memory |
Device Size: | 512 Mbit |
Algorithm Programming method: | SPI |
Memory Organization:
Memory Type |
Attributes(*) |
Included in default Range (Y/N) |
DUT Physical Byte Address(hex) (if this area is selected/Activated) |
BPWin Buffer Byte Address(hex) |
Main Flash Area |
R/W/E |
Yes |
00000000 - 03FFFFFF |
00000000 - 03FFFFFF |
OTP |
R/W/E |
N0 |
04000010 - 040003FF |
04000010 - 040003FF |
| | | | |
Password |
R/W/E |
N0 |
04000400 - 04000407 |
04000400 - 04000407 |
| | | | |
Default Algorithm Range |
--- |
--- |
00000000 - 03FFFFFF |
00000000 - 03FFFFFF |
* R:Read only, W:One time programmable (OTP), R/W:readable and one time programmable (OTP), R/W/E:readable and rewritable if not locked.
Any configurations listed under "Device-Specific" in the menu item Device-> Settings will be written to the DUT during "Program" operation regardless of memory range selection.
512M-bit Serial Flash.
This algorithm uses Standard SPI mode to Program and Verify/Read the device.
The status register bits can be set under Device Config > Configure .
Erase must be selected if device to be programmed already has QE bit enabled.
The default Device Range is set to [0000000h-3FFFFFFh].
Please modify the range under Device Config > Range if any of the Security Registers
need to be included.
The correct password value, located in the range [4000400h-4000407h], may be read only after it is programmed
and before the Password Mode has been selected by programming the Password Protection Mode bit to 0 in the
ASP Register (ASP[2]).
The OTP region is located in the range [4000000h-40003FFh].
The Factory Programmed 128-bit random number located at the beginning of the OTP region cannot be
programmed, and data in this region will not be shown in the Buffer Editor. OTP Lock bits are located
in the Buffer location [4000010h-4000013h] and Reserved bits are located at [4000014h-400001Fh].
The device lock bits may be programmed under Device Congig > Configure. Each Group is devided into
256K Bytes of data.
|
|