Device Support Summary For "Micron MTFC4GACAJCN-1M WT (HS400)"

 
Generated by:BPWin V7.0.9 DeviceSupportUpdate.224 (9/19/2023)
 
Device Parameters

Manufacturer:Micron (ID=13h)
Part Number:MTFC4GACAJCN-1M WT (HS400) (ID=3441h)
8-bit Bytes:4402446336
Memory Regions:0h-F7D3 FFFFh; F7D4 0000h-1 0667 FFFFh
Vcc(program):3.3
Electrical Erase:Yes
Set programming:Yes
Packages:BGA(153)
 
Note

IMPORTANT:
Device Type: eMMC
Device Size: See below
Algorithm Programming Mode: HS400

Memory Organization Before Formatting:
Memory Type

Attributes(*)

DUT Physical Byte Address(hex) BPWin Buffer Byte Address(hex)
Boot Area Partition 1 R/W/E 0000000000-00001FFFFF 0000000000-00001FFFFF
Boot Area Partition 2 R/W/E 0000000000-00001FFFFF 0000200000-00003FFFFF
User Data Area R/W/E 0000000000-00E8FFFFFF 0000400000-00E93FFFFF
Default Algorithm Range --- 0000000000-00E8FFFFFF 0000400000-00E93FFFFF
* R:Read only, W: One time programmable (OTP), R/W: readable and one time programmable (OTP), R/W/E: readable and rewritable if not locked. Any configurations listed under "Device-Specific" in the menu item Device-> Settings will be written to the DUT during "Program" operation regardless of memory range selection.
Special Device Considerations:
1. Default Device Size: 4 GByte
2. Device size after enhancing the full user area: 1,864 MByte
3. Total number of sectors: 7,634,944
4. Write Protect Group Size: 16 MByte
5. High Capacity Write Protect Group Size: 8 MByte
6. MAX_ENH_SIZE_MULT: E9h
7. Serialization Supported: No
8. RPMB partition is not currently supported by this algorithm.
9. General Purpose Partitions 1-4, if any, are mapped directly after the boot partitions. This is followed by the rest of the User Data Area.
10. Sizes and attributes of General Purpose Partitions 1-4 can be set under Device->Settings.
11.Each physical sector on the device has 512 bytes, however, 32 bytes of CRC-16 data must be embedded in the Data Pattern after every sector.
12.Please use Device->Image_Format to create a Data Pattern formatted with the CRC-16 bytes based on MMC specifications.
13.This algorithm verifies data after programming if Program operation is selected.
14.Enabling Erase operation will erase the full boot partitions and user data area.
15.Enhancing the user data area reduces the effective size of the device. Any data after the end of the effective size will be skipped.
16.Only data files formatted through BPWin with the .bpmhs400 extension is supported in this algorithm.
 
= Supported
 
= This is a replacement daughter card that requires a base socket module
 
Automated Production Programmers

Programmer Model:39004900
Algorithm Code Revision:1.11.1
 
BGA Socket Modules (Sorted by Performance)
FVE4ASML153BGL
FVE4ASMC153BGJ
FVE4ASMC153BGZ
 
Manual Production Programmers

Programmer Model:19002900
Algorithm Code Revision:1.11.1
 
BGA Socket Modules (Sorted by Performance)
FVE4ASML153BGL
FVE4ASMC153BGJ
FVE4ASMC153BGZ
 
Copyright © 2023, BPM Microsystems
 

Last Updated: 08/05/2021