IMPORTANT:
Device Type: | Flash Memory |
Device Size: | 64 Mbit |
Algorithm Programming method: | Parallel Programming |
Memory Organization:
Memory Type |
Attributes(*) |
Included in default Range (Y/N) |
DUT Physical Word Address(hex) (if this area is selected/Activated) |
BPWin Buffer Byte Address(hex) |
Main Flash Area |
R/W/E |
Yes |
0000_0000 - 003F_FFFF |
0000_0000 - 007F_FFFF |
SecSi sector |
R/W |
N0 |
0040_0000 - 0040_007F |
0080_0000 - 0080_00FF |
| | | | |
Default Algorithm Range |
--- |
--- |
0000_0000 - 003F_FFFF |
0000_0000 - 007F_FFFF |
* R:Read only, W:One time programmable (OTP), R/W:readable and one time programmable (OTP), R/W/E:readable and rewritable if not locked.
Any configurations listed under "Device-Specific" in the menu item Device-> Settings will be written to the DUT during "Program" operation regardless of memory range selection.
Special Device Considerations: |
|
The SecSi sector can be purchased programmed and locked from the factory.
If this is the case, this sector needs to be excluded from programming and verification ranges as this data could have a unique number.
The configuration option for the factory lock is used to indicate the status of the chip.
If this option is different than the state of the chip during verification or compare, it will cause an error.
If the part has not been locked by the factory, the user can treat this sector as an additional memory sector with OTP sector protection.
Persistent Protection bit(PPB) feature is setup under Device Configure. PPB is one time programmable(OTP). | |